Download here: http://gg.gg/ufhr0
*Mac 2000 Profile Ii
*Mac 2000 Profile
*Mac 2000 Profile ManualGE MAC 2000EKG and ECG Machines
*Bombilla mac 2000 profile HOLA un saludo a todos los luminotecnicos del foro, mi inquietud o mas el problema q tengo es q en la empresa hay unas mac 2000 y algunas no todas se estan apagando, por ejemplo estoy en el show y de un momento a otro se le apaga la bombilla a una y luego de al rededor de 2 minutos prende de nuevo y despues le pasa lo.
*About the HMI 1200 W/S lamp The MAC 2000 Profile comes with a double-ended OSRAM HMI 1200 W/S discharge lamp installed. This highly-efficient short-arc source provides an exceptionally stable 6000K color TO P temperature, a color rendering index greater than 90, and an average life of 750 hours.
*We use cookies to improve your experience on our site and to enhance and personalize your experience across the 4Wall portfolio of brands, including UsedLighting.com and NewLighting.com. Learn more, including how to manage your privacy settings.
*Martin MAC 2000 Profile II Demo Video @ ProAAL.com.
Apple’s Mac OS X MAC framework is an implementation of the TrustedBSD MAC framework. A limited high-level sandboxing interface is provided by the command-line function sandboxinit. See the sandboxinit manual page for documentation. Oracle Label Security is an implementation of mandatory access control in the Oracle DBMS.GE MAC 2000 Features:
The GE Mac 2000 from GE Healthcare helps the clinician make a fast and accurate diagnosis with the power of the Marquette 12SL analysis program. It’s the proven #1 diagnostic support you need, in an ECG system that’s intuitive and easy to use.
The MAC 2000 increases productivity in the hospital, your practice, and pharma clinical trials. It connects seamlessly with your existing environment, immediately making it easier to acquire, print, store, and transmit ECG data. Okidata c830 drivers for mac. It’s your link to productivity, however, you need to connect.GE MAC 2000 Specifications:Signal Processing:
*ECG Interpretation: Marquette 12SL ECG Analysis Program for Adults and Pediatrics.
*Computerized measurements: 12-lead analysis.
*ECG analysis frequency: 500 or 1000 samples/second/channel.
*Digital sampling rate: 16000 samples/second/channel for normal data acquisition.
*Pace sampling rate: 75K samples/second/channel.
*ECG on-screen preview: an on-screen preview of acquired 10 second ECG waveform.
*Acquisition mode: Provides 10 seconds of instantaneous ECG acquisition.
*Dynamic range: AC Differential ±5 mV, DC offset ±300 mV.
*Resolution: 4.88 µV +/-1% per LSB @ 500 SPS.
*Frequency range: 0.04 to 150 Hz.
*Low cut off frequency: 0.04 Hz (ADS off), 0.56 Hz (ADS On).
*High cut off frequency: Configurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz.
*Common mode rejection: >135 dB (with 50/60 Hz filter ON.)
*Input impedance: >10MΩ @ 10 Hz.
*Patient leakage: <10µA (Normal Condition), <50µA (Single Fault Condition).
*Lead detection: All disconnected lead detection except RL & RA.
*Heart rate meter: 30 to 300 BPM.
*Operating system: Microsoft® Windows® CE 6.0.
*Start-up time: Less than 30 seconds.Patient Information:
Patient ID, secondary patient ID, last name, first name, height, weight, gender, race, pacemaker patient, systolic BP, diastolic BP, location number, room, order number, phone number, medication, ordering physician, referring physician, attending physician, technician, test indication.Display:
*Display Type: 7 in. color TFT display with support of minimum 32K colors.
*Display Resolution: WVGA resolution – 800 x 480.
*Display Data: Heart rate, patient ID, clock, battery power indicator, waveforms, lead labels, speed, gain and filter settings, warning messages, prompts, help messages, and 12-lead display.Writer:
*Writer technology: Thermal dot array.
*Writer speed: 5, 12.5, 25, and 50 mm/s.
*Writer sensitivity/gain: 2.5, 5, 10, 20, 40 mm/mV.
*The number of traces: Up to 12 ECG traces.
*Writer speed accuracy: 5, 12.5 mm/s @ ±5% and 25, 50 mm/s @ ±2%.
*Writer amplitude accuracy: ±5%.
*Writer resolution: Horizontal 40 dots/mm @ 25 mm/s, 8 dots/mm vertical.
*Paper type: Z-fold Thermal Paper with pre-printed grid and perforation with Queue mark or Queue hole.
*Paper size: 215 mm x 280 mm (letter) and 210 mm x 295 mm (A4), and 214.2 mm x 279.4 mm. (Modified Letter)Keyboard:
*Membrane keyboard with tactile feedback – Soft function keys, alphanumeric keys (Qwerty key set), writer controls and Trim Pad cursor controls.Operating Modes and Additional Features:
*Resting ECG mode: Records and prints 12-lead resting ECGs with 10 seconds duration as a standard feature.
*Arrhythmia mode: Continuously monitors ECG and prints report when arrhythmia events of the user-selected class occur.
*Exercise mode: Exercise mode for exercise stress testing.
*RR Analysis mode: RR analysis for RR intervals analysis.
*Hookup advisor: Provides a visual indication of signal quality.
*Multi-language support: Supports 19 languages in User Interface and 31 languages in User Manual.
*Order manager: Provides an interface for managing orders.
*ADT Query: Provides an interface for querying patient demographics.
*File manager: Provides an interface for managing ECG Records.
*System setup: Provides an interface for managing Device Configuration.Stress / Pharma Application Options:
*Stress testing application: Ergometers supported include: eBikeTreadmills supported include: T2100, T2000.
*Master’s Step device without the interface. (acoustic signal only.)
*Note: Ergometer, Master Step, and Treadmill sold separately.
*Pharma application: Pharma application options include:
*Audit trail export.
*CT Data Guard
*High-security login protection.
*External Peripherals:
*Keyboard: Standard USB English Keyboard.
*Barcode reader: Jadak-1799.Communication:
*Internal modem, Secured Digital card, Serial, LAN, and WIFI communicate outbound to MUSE and CardioSoft.
*Internal modem, LAN, and WIFI communicates inbound to MUSE.
*RS232 serial cable: ECG Transmission with A5 & CSI Protocol.
*Internal Modem: ECG Transmission with CSI Protocol.
*Supported MUSE/CardioSoft: Compatible with MUSE V7.1.1 and MUSE 8.0.1/CardioSoft V6.51, CardioSoft V6.61, and CardioSoft V6.71.
*RJ45 Wired LAN: ECG Transmission with CSI, DCP Protocol, and Shared Directory.
*Wireless LAN (WIFI): ECG Transmission with CSI, DCP Protocol, and Shared Directory.Storage:
*ECG Storage Format: XML format, Hilltop format, PDF storage format.
*Storage Capacity: Internal storage of 100 or 200 ECGs.Electrical:
*Power supply: Internal AC/DC or battery operation.
*AC/DC operation specifications:
*Input voltage: 100 to 240 VAC ±10%.
*Input current: Maximum 1.5A in voltage range 115 V to 230 V AC.
*Input frequency: 47 to 63 Hz.
*Battery specifications:
*Battery type: Replaceable and rechargeable, Lithium Ion.
*Battery capacity: 14.4V and 16.8V Max @ 2.2 AH ±10%; 100 single page resting ECG recordings or 3 hours (typical) of continuous monitoring without printing, at a minimum.
*Battery charge time: Approximately 3.5 hours after low battery shut down. (With device off.)Dimensions:Mac 2000 Profile Ii
*Height: 20 cm.
*Width: 39 cm.
*Depth: 33 cm.Weight:Mac 2000 Profile
*Approx. 5 Kg including battery, without paper.Final ThoughtsMac 2000 Profile Manual
Is there anything that you like about the GE MAC 2000 that we didn’t list? Leave a comment down below! Do you like the MAC 2000 or another EKG? The worlds hardest game. Let us know which EKG Machine is your favorite!RelatedCurrently unavailable online. Please call for information.Please call 0114 243 3896 or email sales@numed.co.uk for more information.
The MAC 2000 from GE Healthcare is a high performance 12-Lead resting ECG machine which helps the clinician make a fast and accurate diagnosis with the power of the Marquette 12SL analysis program. MAC 2000 features a 7’ colour display, A4 print out and is supplied with a market leading 5 year warranty.
Using the included Intelligent Integration Interface (I3) software*, the MAC 2000 ECG system is fully integrated with all the leading primary care clinical systems from EMIS, TPP and Vision. The software automatically files a high quality ECG report (as a PDF) and a coded result to the patient’s record on test completion.
MAC 2000 ECG enables your practice or clinic to be more productive, with tools such as HookUp Advisor. This allows you to identify a quality signal before acquisition, helping avoid costly repeat ECGs. It’s all part of a smarter, simpler workflow that lets you do more in less time—so you can focus on patients.Main Features
*Marquette 12SL ECG Analysis program for clinical support
*Supports paperless workflow with I3 integration
*PDF & XML export capabilities
*Internal storage for 200 ECGs
*Produces A4 paper reports
*Connectivity with serial port or SD card
*Automatic capture of 10 second ECG with 1 touch operation
*ongoing license cost applies 2013 14 chris neil game worn helmetottawa senators game used jersey.
Download here: http://gg.gg/ufhr0

https://diarynote.indered.space

コメント

最新の日記 一覧

<<  2025年7月  >>
293012345
6789101112
13141516171819
20212223242526
272829303112

お気に入り日記の更新

テーマ別日記一覧

まだテーマがありません

この日記について

日記内を検索